Portable Flue Gas Analyser
Portable Flue Gas Analyzer, Model Energy Saver 2014 (ES 2014)
Total Solution for Boiler Efficiency Analysis
- Measures O2 , CO & Stack Temperature, Calculates
CO2 , Efficiency, Losses, Excess air, Net Temperature,
CO / CO2 Ratio & Poison Index. - Can store up to 100 sets of data.
- Powerful Windows Software for Analyzer Data Communication.
- 8-bit Micro Controller
- Rechargeable Nickel Metal Hydride Battery
- Suction Pump with 300 mbar w.r.t. atmosphere
- Borosilicate Filter with 0.1 micron porosity
- Gas probe with thermocouple and condensate trap
- RS-232 interface and multi functional PC program
- Automatic zeroing when the analyzer is switched ON
- All parameters programmable
- 20 common fuels
Actual Parameters | Resolution | Accuracy | Range |
Flue Temperature with probe with suitable probe | 0.10 C | ±2.00 C | 0 – 1200 C |
Inlet Temperature | 0.10 C | ±0.10 C | 0 – 500 C |
Oxygen | 0.1% | ±0.2% | 0 – 21% |
Carbon Monoxide (Standard) | 1 ppm | ±20 ppm<500 ppm | 0 -10000 ppm±5%>500 ppm |
Derived Parameters | |||
Carbon Dioxide | 0.1% | ±0.3% of reading | 0 – 20% |
Efficiency | 0.1% | ±1.0% of reading | 0 – 120% |
Losses | 0.1% | ±1.0% of reading | 0 – 99.99% |
Excess air | 0.1% | ±0.2% | 0 – 2885.0% |
Temp (Net) Standard | 10 C | ±20 C | 0 – 600 C |
CO/CO Ratio | 0.0001 | ±0.0001 | 0 – 0.9999 |
Poison Index | 0.01% | 0.01% | 0 – 99.99% |
Ambient Temperature: 0-50 degC
Humidity: 0-95 % rh
Repeatability: ± 1% of reading
Power Supply: 80-230 VAC, 50 Hz, Adaptor
Area Classification: General Purpose